VLT® Servo Drive System ISD 510/DSD 510
Operating Guide
1.
Open SIMOTION SCOUT
2.
Select the menu [Project → Accessible nodes].
3.
If accessible nodes are found in another subnet, the Add IP addresses / subnet masks window is displayed and shows them.
Illustration 98: Accessible Nodes
4.
Click on Yes to accept the addresses.
5.
The IP address/subnet mask is now added.
-
If >1 Danfoss servo drive is used in the same PROFINET
dress.
-
The last number of the IP address is the ID that is used in the VLT
-
When the Accessible nodes tab is closed, the addresses are retained. The newly added addresses are only discarded when
SIMOTION SCOUT
is closed.
®
-
IP addresses and subnets can also be added using PRONETA.
6.17.4.4 Direct Communication
6.17.4.4.1 Overview
For Ethernet-based fieldbus communication (direct communication), the VLT
face on the VLT
Servo Toolbox host system. Do not use this network interface simultaneously for any other communication.
®
Danfoss A/S © 2020.08
.
®
N O T I C E
®
N O T I C E
network, each servo drive must have a different name and IP ad-
Servo Toolbox software to identify the device.
®
Servo Toolbox must use a dedicated network inter-
®
Commissioning
AQ262449648484en-000101 / 175R1135 | 135

Advertisement

Table of Contents
loading