07/11/02 09:49:48 61TA0000_230_0076
5. Measure the voltage between the audio-HVAC
(sub) display unit 12P connector No. 9 terminal and
body ground.
*17
AUDIO-HVAC (SUB) DISPLAY UNIT 12P CONNECTOR
Is there less than 0.5 V ?
YES
NO
−
(sub) display 12P connector terminal No. 9 and
body ground (G401).
6. Turn the ignition switch to LOCK (0).
7. Disconnect audio unit connector B (20P) and the
audio-HVAC (sub) display unit 12P connector.
GND (BLK)
Wire side of female terminals
−
Go to step 6.
Repair open in the wire between audio-HVAC
8. Check for continuity between audio unit connector
B (20P) and the audio-HVAC display unit 12P
connector according to the table.
Audio unit
Audio-HVAC
connector
display unit
connector
B6
2
[
]
B7
B12
1
[
]
B17
B11
4
[ ]
: 1 CD type
Except 1 CD
AUDIO UNIT CONNECTOR B (20P)
Wire side of female terminals
1 CD type
AUDIO UNIT CONNECTOR B (12P)
Wire side of female terminals
AUDIO-HVAC (SUB) DISPLAY UNIT 12P CONNECTOR
Wire side of female terminals
Is there continuity?
−
YES
Go to step 9.
NO
−
Repair open in the wire(s) between the audio
unit and audio-HVAC (sub) display unit.
Wire color
RED
GRN
BLU
*18
(cont'd)
23-75