07/11/02 09:43:55 61TA0000_240_0040
SRS
ODS Unit Calibration
When you replace the SRS unit, front passenger's
weight sensors, or the ODS unit, calibrate the ODS unit.
While calibrating the ODS unit, observe these
precautions:
• Make sure all components of the front passenger's
seat are correctly installed.
• Make sure nothing is on or under the front passenger's
seat.
• Make sure there is nothing in the front passenger's
seat-back pocket.
• Keep the windows and the moonroof are closed.
• Do all calibration procedures, except test-driving, in
the service bay.
• Make sure the vehicle is on level ground.
• Keep the A/C and the heater off.
• Do not touch the front passenger's seat until you are
prompted to or when you have completed the
calibration.
• Do not expose the front passenger's seat to sudden
temperature changes.
24-40
1. Position the front passenger's seat to the rearmost
position, and adjust the seat-back to the most
forward position. Do not move the seat from this
position.
2. Connect the HDS to the data link connector (DLC)
(A).
A
3. Make sure the HDS communicates with the vehicle
and the SRS unit. If it does not communicate,
troubleshoot the DLC circuit (see page 11-208).
4. Drive the vehicle, and accelerate to 20 mph
(36 km/h), then stop on level ground.
5. From the Main Menu, select SRS, then Calibration,
then Misc Test, then select SWS INITIALIZATION,
and follow the prompts until the calibration is
complete.
TA08A00H46400043081BBAT01
*02