Honda Accord 2008 Manual page 2868

Hide thumbs Also See for Accord 2008:
Table of Contents

Advertisement

07/11/02 09:50:47 61TA0000_240_0145
DTC 46-1x (''x'' can be 0 thru 9 or A thru F):
No Signal From the Right Side Impact Sensor
(second) (2-door)
Special Tools Required
• SRS inflator simulator 07SAZ-TB4011A
• SRS simulator lead L 070AZ-SNAA300
NOTE:
• Before doing this troubleshooting procedure, review
SRS Precautions and Procedures (see page 24-23)
and General Troubleshooting Information (see page
24-35).
• Before replacing the SRS unit, check the SRS unit
software version with the HDS. If the software
version is not the latest, update the SRS unit software
(see page 24-38) and retest.
1. Clear the DTC memory (see page 24-36).
2. Turn the ignition switch to ON (II), then wait for 10
seconds.
3. Read the DTC (see page 24-36).
Is DT C 46-1x indicated?
YES
• If DTC 46-11 is indicated alone or DTC 46-11 and
B2-12 is indicated, go to step 4.
• If DTC 46-1x except 46-11 is indicated alone,
faulty left side impact sensor (second); replace
the left side impact sensor (second) (see page
24-228).
• If DTC 44-11 and 46-11 are indicated, faulty left
side impact sensor (first); replace the left side
impact sensor (first) (see page 24-226).
• If DTC 46-11 and B2-11 are indicated, faulty rear
safing sensor; replace the rear safing sensor
(see page 24-229).
NO
Intermittent failure, the system is OK at this
time. Go to Troubleshooting Intermittent Failures
(see page 24-37). If another DTC is indicated,
troubleshoot the DTC.
4. Turn the ignition switch to LOCK (0).
5. Do the battery terminal disconnection procedure
(see page 22-89), then wait for 3 minutes.
6. Disconnect the SRS floor wire harness 2P
connector from the right side impact sensor
(second) (see page 24-228).
7. Disconnect the SRS floor wire harness 4P
connector from the rear safing sensor (see page
24-229).
8. Measure the resistance between the No. 1 and the
No. 2 terminals of SRS floor wire harness 2P
connector. There should be an open circuit or at
least 1 M .
SRS FLOOR WIRE HARNESS 2P CONNECTOR
Terminal side of female terminals
Is the resistance as specif ied?
YES
Go to step 9.
NO
Short in the SRS floor wire harness; replace
the SRS floor wire harness.
9. Measure the resistance between the No. 1 terminal
of SRS floor wire harness 2P connector and body
ground, and between the No. 2 terminal and body
ground. There should be an open circuit or at least
1 M .
SRS FLOOR WIRE HARNESS 2P CONNECTOR
Terminal side of female terminals
Is the resistance as specif ied?
YES
Go to step 10.
NO
Short to ground in the SRS floor wire harness;
replace the SRS floor wire harness.
TA08AB2K791000R461XFAAT00
*51
*52
(cont'd)
24-145

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents