Monitoring Variables Descriptions - Delta ASDA-A3 Series User Manual

Hide thumbs Also See for ASDA-A3 Series:
Table of Contents

Advertisement

Parameters
Table 8.3 Monitoring variables descriptions
Item
Monitoring
8
code
Format
Category
Monitoring
method
Panel
display
Mapping
The property code of each monitoring variable is described in the following table:
Property
B
D1 D2
Dec
Hex
Monitoring variables are described in the following table by the code sequence:
Code
000 (00h)
001 (01h)
002 (02h)
003 (03h)
004 (04h)
005 (05h)
006 (06h)
007 (07h)
8-206
Each monitoring variable has a code, and you can use P0.002 to set the code and
monitor the variable.
Each monitoring variable is stored in the 32-bit format (long integer) of the servo drive.
Basic variables / expansion variables:
1. Basic variables: variables (P0.002 = 0 – 26) within the cycle; in monitoring mode,
you can display the variables by using the UP / DOWN keys on the panel.
2. Expansion variables: variables other than basic variables. (P0.002 = 27 – 127)
Panel display / mapping:
1. Panel display: monitor with the panel
2. Mapping: monitor variables or parameters by mapping parameters
1.
Use the MODE key to switch to the monitor mode and press the UP / DOWN keys to
select the variable to monitor.
2.
Input the variable code to monitor into P0.002 and start monitoring.
Press the SHIFT key on the panel to switch between high and low digit display;
Press the SET key on the panel to switch between decimal and hexadecimal display.
1.
Parameters that support monitoring variable mapping: for P0.009 – P0.013,
please refer to Section 8.3 Parameter descriptions.
2.
You can read monitoring variables through communication using mapping
parameters.
3.
The value of the mapping parameter (P0.009 – P0.013) is the content of the basic
variables (17h, 18h, 19h, 1Ah). To monitor P0.009, set P0.017 to the value to read
(please refer to P0.002). You can read the data specified by P0.017 through
communication or the monitor panel (set P0.002 to 23). When the panel displays
"VAR-1", it indicates the content value of P0.009.
BASE: basic variables, you can select with the UP / DOWN keys on the panel.
Decimal place displayed on panel: D1 indicates 1 decimal place, D2 indicates 2 decimal
places.
Only decimal display is available on the panel, and you cannot switch to hexadecimal
display by pressing the SET key.
Only hexadecimal display is available on the panel, and you cannot switch to decimal
display by pressing the SET key.
Variable name /
property
Feedback position
(PUU) B
Position command
(PUU) B
Position deviation
(PUU) B
Feedback position
(pulse) B
Position command
(pulse) B
Position deviation
(pulse) B
Pulse command
frequency B
Speed feedback
B D1 Dec
Description
Description
Description
Current feedback position of the motor encoder. Unit: Pulse
of User Unit (PUU).
Current coordinate of the Position command. Unit: Pulse of
User Unit (PUU).
PT mode: number of pulse commands received by the drive.
PR mode: absolute coordinates of the Position command.
Deviation between the Position command and the feedback
position. Unit: Pulse of User Unit (PUU).
Current feedback position of the motor encoder.
Unit: Encoder unit (pulse).
Current coordinate of the Position command. Unit: Encoder
unit (pulse). This is the command after passing E-Gear.
Deviation between the Position command and the feedback
position. Unit: Encoder unit (pulse).
Frequency of the pulse command received by the drive.
Unit: Kpps. Applicable to PT / PR mode.
Current motor speed. Unit: 0.1 rpm.
The low-pass filter has been applied to this value to make it
more stable.
ASDA-A3
Revision December, 2017

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents