Parameter Definitions; Control Mode Description; Special Symbol Description - Delta ASDA-A3 Series User Manual

Hide thumbs Also See for ASDA-A3 Series:
Table of Contents

Advertisement

Parameters

8.1 Parameter definitions

The servo drive parameters are divided into eight groups. The first character after the start code
P is the group character and the following three characters are the parameter indicator. The
8
communication address is the combination of the group number and the three-digit number,
expressed in hexadecimal. The parameter groups are:
Group 0: Monitoring parameters
Group 1: Basic parameters
Group 2: Extension parameters
Group 3: Communication parameters
Group 4: Diagnosis parameters
Group 5: Motion control parameters
Group 6: PR parameters
Group 7: PR parameters

Control mode description:

PT: Position control (command input through terminal block)
PR: Position control (command sent from internal register)
S: Speed control
T: Torque control
DMC: DMCNET control

Special symbol description:

Icon of parameter
property
8-2
Read-only parameter. Can only read the value of the parameter.
For example, P0.000, P0.010, P4.000, etc.
Parameter cannot be changed when servo is in Servo On status.
For example, P1.000 and P1.046.
Parameter changes become valid after cycling the power.
For example, P1.000 and P3.000.
Parameter resets to its default value after cycling the power.
For example, P2.031 and P3.006.
(Example: P0.xxx)
(Example: P1.xxx)
(Example: P2.xxx)
(Example: P3.xxx)
(Example: P4.xxx)
(Example: P5.xxx)
(Example: P6.xxx)
(Example: P7.xxx)
Description
ASDA-A3
Revision December, 2017

Hide quick links:

Advertisement

Table of Contents
loading