ASDA-A3

P5.xxx Motion control parameters

P5.000★■
Default:
Factory setting
Unit:
-
Format:
DEC
Settings:
The low bit is the subversion of the firmware.
P5.001 –
Reserved
P5.002
P5.003
Default:
0xEEEFEEFF
Unit:
-
Format:
HEX
Settings:
The parameter setting is divided into D, C, B, A, W, Z, Y, X (hexadecimal), including:
1.
Deceleration time when activating the auto-protection function: OVF (DO.0x11, Position command /
feedback overflows), CTO (communication timeout AL020), SPL, SNL, PL, NL
2.
Deceleration time for stop command: STP
Digit
Function
Range
Use 0 – F to index the deceleration time of P5.020 – P5.035. For example: if you set X to A,
then the deceleration time of PL is determined by P5.030.
P5.004
Default:
0x0
Unit:
-
Format:
HEX
Settings:
U
Z
Y
X
Y
Revision December, 2017
Firmware subversion
Deceleration time for auto-protection
D
C
STP
PFQS
CTO
0 – F
0 – F
0 – F
Homing methods
X
Homing method
Z pulse setting
Control mode: All
Setting range: -
Data size:
32-bit
Control mode: All
Setting range: 0x00000000 – 0xFFFFFFFF
Data size:
32-bit
B
A
W
OVF
SNL
0 – F
0 – F
Control mode: PR
Setting range: 0 – 0x128
Data size:
16-bit
Z
U
Address: 0500H
0501H
Address: 0506H
0507H
Z
Y
X
SPL
N
PL
0 – F
0 – F
0 – F
Address: 0508H
0509H
Limit setting
Reserved
Parameters
8
8-109