ASDA-A3
P1.021 –
Reserved
P1.022
P1.023
Default:
0
Unit:
Pulse unit of compare source
Format:
DEC
Settings:
When using the Compare function, you can add the translation value to the data array to be used as the
actual comparison data:
For example:
If the data array for comparison is DATA_ARRAY[100] = 2000 and P1.023 = 40,
Then the actual comparison value = 2000 + 40 = 2040.
Note:
1.
This parameter is non-volatile.
2.
P1.024: after the value takes effect, if P1.019.Z [Bit 0 = 1], then it automatically resets.
3.
You can display CMP_DATA with the monitoring variable V25h (037).
P1.024■
Default:
0
Unit:
Pulse unit of compare source
Format:
DEC
Settings:
When using the Compare function, you can add the translation value to the data array to be used as the
actual comparison data:
Note:
1.
This parameter is volatile.
2.
After the parameter takes effect, if P1.019.Z [Bit 0 = 1], then it automatically resets.
3.
You can display CMP_DATA with the monitoring variable V25h (037).
Revision December, 2017
Compare - Data translation (non-volatile)
CMP_DATA = DATA_ARRAY[*] + P1.023 + P1.024
Compare - Data translation (reset automatically)
CMP_DATA = DATA_ARRAY[*] + P1.023 + P1.024
Control mode: ALL
Setting range: -10000000 to +100000000
Data size:
32-bit
Control mode: ALL
Setting range: -32768 to +32767
Data size:
16-bit
Parameters
Address: 012EH
012FH
Address: 0130H
0131H
8-39
8