ASDA-A3
P0.008★
Default:
0
Unit:
Hour
Format:
DEC
Settings:
Displays the total servo drive operation time. The unit is in hours and durations of less than 1 hour are not
recorded. The recorded hours are saved when the servo powers off.
DCBA
Servo on time
h
High bit
P0.009★■
Default:
0
Unit:
-
Format:
DEC
Settings:
Set the value to be monitored in P0.017 through the drive panel or communication. Please refer to
P0.002. To get the status, the communication port must read the communication address.
For example, if you set P0.017 to 3, when accessing P0.009, the panel displays the total number of
feedback pulses of the motor encoder. If accessing the data through MODBUS communication, it reads
two 16-bit values (0012H and 0013H) as a single 32-bit value. (0013H : 0012H) = (Hi-word : Low-word).
Set P0.002 to 23 and the panel displays VAR-1 as the value of P0.009.
P0.010★■
Default:
-
Unit:
-
Format:
DEC
Settings:
Set the value to be monitored in P0.018 through the drive panel or communication. Please refer to
P0.002. To get the status, the communication port must read the communication address. Set P0.002 to
24 and the panel displays VAR-2 as the value of P0.010.
Revision December, 2017
Total servo drive operation time
D C B A
Status monitoring register 1
Status monitoring register 2
Control mode: All
Setting range: 0 – 65535
Data size:
16-bit
U Z Y X
UZYX
Servo power applied time
L
Low bit
Control mode: All
Setting range: -
Data size:
32-bit
Control mode: All
Setting range: -
Data size:
32-bit
Parameters
Address: 0010H
0011H
Address: 0012H
0013H
Address: 0014H
0015H
8-15
8