ASDA-A3
P2.024
Default:
0
Unit:
-dB
Format:
DEC
Settings:
This is the first Notch filter attenuation level. For example, an attenuation level of 5 indicates -5 dB. Set
this parameter to 0 to disable the Notch filter function.
P2.025
Operation
Panel / software
interface:
Default:
1.0
Unit:
1 ms
Setting range: 0.0 – 100.0
Format:
One decimal
Example:
1.5 = 1.5 ms
Settings:
Set the time constant for the low-pass filter for resonance suppression. Set this parameter to 0 to disable
the low-pass filter.
P2.026
Default:
0
Unit:
rad/s
Format:
DEC
Settings:
Increasing this parameter can increase the damping of the speed loop. Setting the value of P2.026 to
equal P2.006 is recommended. Please see the following for setting P2.026:
1.
In Speed mode, increase the value of this parameter to reduce speed overshoot.
2.
In Position mode, decrease the value of this parameter to reduce position overshoot.
P2.027
Default:
0x0000
Unit:
-
Format:
HEX
Revision December, 2017
Notch filter attenuation level (1)
Resonance suppression low-pass filter
Communication
10
0.1 ms
0 – 1000
DEC
15 = 1.5 ms
Anti-interference gain
Gain switching condition and method selection
Control mode: All
Setting range: 0 – 40
Data size:
16-bit
Control mode: All
Data size:
16-bit
-
-
-
-
Control mode: All
Setting range: 0 – 1023
Data size:
16-bit
Control mode: All
Setting range: 0000h – 0x0018
Data size:
16-bit
Parameters
Address: 0230H
0231H
Address: 0232H
0233H
-
-
-
-
Address: 0234H
0235H
Address: 0236H
0237H
8-67