ASDA-A3
P2.065
Default:
0
Unit:
-
Format:
-
Settings:
7
6
Bit
15
14
Bit
Bit 0 – Bit 2, Bit 4, Bit 5, Bit 7, and Bit 14: reserved, please set to 0.
Bit 3: set the method for regenerative energy consumption.
0: determined by the servo's internal algorithm.
1: determined by the DC bus voltage.
Bit 6: in PT mode, set the pulse error (pulse frequency is too high) protection function.
0: enable the pulse error protection function.
1: disable the pulse error protection function.
Bit 8: U, V, W wiring error detection function.
1: enable the U, V, W wiring error detection function.
Bit 9: U, V, W wiring cut-off detection function.
1: enable the U, V, W wiring cut-off detection function.
Bit 10: ZCLAMP function selection. The ZCLAMP function is enabled when the following conditions are
met. Condition 1: Speed mode; Condition 2: DI.ZCLAMP is on; Condition 3: motor speed is slower
than the value of P1.038.
0: command source is the analog voltage. The ZCLAMP function uses the analog Speed
command without acceleration / deceleration to determine if this function should be enabled.
The motor is clamped at the position where ZCLAMP conditions are met.
0: command source is the internal register. ZCLAMP function uses the register Speed command
with acceleration / deceleration to determine if this function should be enabled. The motor is
clamped at the position where ZCLAMP conditions are met.
Revision December, 2017
Special bit register
5
4
3
2
1
12
11
13
10
9
Control mode: PT / PR / S / Sz
Setting range: 0 – 0xFFFF
Data size:
-
0
8
Parameters
Address: 0282H
0283H
8-79
8