ASDA-A3
P4.008★
Default:
-
Unit:
-
Format:
HEX
Settings:
Use this communication parameter to read and check that the five keys (MODE, UP, DOWN, SHIFT,
and SET) can function normally.
P4.009★
Default:
-
Unit:
-
Format:
HEX
Settings:
There is no difference whether reading by panel or through communication.
P4.010■
Default:
0
Unit:
-
Format:
DEC
Settings:
0: reserved
1: execute analog speed input offset
adjustment
2: execute analog torque input offset
adjustment
3: execute current encoder (V phase) offset
adjustment
Note: The adjustment function must be enabled by setting P2.008. When adjusting, the external analog voltage wiring
connected to the torque needs to be removed completely and must be in Servo Off status.
P4.011
Default:
Factory setting
Unit:
-
Format:
DEC
Settings:
Manually adjust the offset. The function must be enabled by setting P2.008. Do not change the auxiliary
adjustment as this parameter cannot be reset.
Revision December, 2017
Input status of servo drive panel (read-only)
Digital output status (read-only)
Adjustment function
Analog speed input (1) offset adjustment
Control mode: All
Setting range: Read-only
Data size:
16-bit
Control mode: All
Setting range: 0 – 0x1F
Data size:
16-bit
Control mode: All
Setting range: 0 – 6
Data size:
16-bit
4: execute current encoder (W phase) offset
adjustment
5: execute 1 – 4 offset adjustment
6: execute IGBT ADC adjustment
7 – 14: reserved
Control mode: All
Setting range: 0 – 32767
Data size:
16-bit
Parameters
Address: 0410H
0411H
Address: 0412H
0413H
Address: 0414H
0415H
Address: 0416H
0417H
8-105
8