Parameters
P1.090
Default:
8
Unit:
Format:
Settings:
Anti-resonance frequency for the first set of low frequency vibration elimination.
P1.091
Default:
Unit:
Format:
Settings:
Attenuation rate for the first set of low frequency vibration elimination.
P1.092
Default:
Unit:
Format:
Settings:
Setting method is the same as for the first set of vibration elimination P1.089.
P1.093
Default:
Unit:
Format:
Settings:
Anti-resonance frequency for the second set of low frequency vibration elimination.
P1.094
Default:
Unit:
Format:
Settings:
Attenuation rate for the second set of low frequency vibration elimination.
P1.095 –
P1.096
8-58
First set of vibration elimination - Resonance frequency
4000
0.1 Hz
DEC
First set of vibration elimination - Resonance difference
10
0.1 dB
DEC
Second set of vibration elimination - Anti-resonance
frequency
4000
0.1 Hz
DEC
Second set of vibration elimination - Resonance frequency
4000
0.1 Hz
DEC
Second set of vibration elimination - Resonance difference
10
0.1 dB
DEC
Reserved
Control mode: PT / PR
Setting range: 10 – 4000
Data size:
16-bit
Control mode: PT / PR
Setting range: 10 – 4000
Data size:
16-bit
Control mode: PT / PR
Setting range: 10 – 4000
Data size:
16-bit
Control mode: PT / PR
Setting range: 10 – 4000
Data size:
16-bit
Control mode: PT / PR
Setting range: 10 – 4000
Data size:
16-bit
ASDA-A3
Address: 01B4H
01B5H
Address: 01B6H
01B7H
Address: 01B8H
01B9H
Address: 01BAH
01BBH
Address: 01BCH
01BDH
Revision December, 2017