ASDA-A3
8.3 Parameter descriptions
P0.xxx Monitoring parameters
P0.000★
Default:
Factory setting
Unit:
-
Format:
DEC
Settings:
Displays the firmware version of the servo drive.
■
P0.001
Default:
-
Unit:
-
Format:
HEX
Settings:
For the list of alarms, please refer to Section 11.1 Alarm list.
P0.002
Default:
0
Unit:
-
Format:
DEC
Settings:
The panel displays some parameters. Input the monitoring variable to P0.002 in order to view changes
to the variable on the panel. For the list of monitoring variables, please refer to Table 8.3 Monitoring
variables descriptions.
Revision December, 2017
Firmware version
Current drive alarm code (Seven-segment display)
Drive status
Control mode: All
Setting range: -
Data size:
16-bit
Control mode: All
Setting range: 0X0000: alarm clear (same as
DI.ARST).
0x0001 - 0xFFFF: displays the alarm
code (not writable).
Data size:
16-bit
Control mode: All
Setting range: -300 to +127
Data size:
16-bit
Parameters
Address: 0000H
0001H
Address: 0002H
0003H
Address: 0004H
0005H
8-13
8