Parameters
Y: PR triggered when EV2 is on
0: no action
1 – D: execute PR# 51 – 63
8
Z: PR triggered when EV3 is on
0: no action
1 – D: execute PR# 51 – 63
U: PR triggered when EV4 is on
0: no action
1 – D: execute PR# 51 – 63
P5.099
Default:
Unit:
Format:
Settings:
U
X
Y
X: PR triggered when EV1 is off
0: no action
1 – D: execute PR# 51 – 63
Y: PR triggered when EV2 is off
0: no action
1 – D: execute PR# 51 – 63
Z: PR triggered when EV3 is off
0: no action
1 – D: execute PR# 51 – 63
U: PR triggered when EV4 is off
0: no action
1 – D: execute PR# 51 – 63
8-148
PR# triggered by event falling-edge
0x0
-
HEX
Z
Y
X
PR triggered by EV1 falling-edge
PR triggered by EV2 falling-edge
Control mode: PR
Setting range: 0x0000 – 0xDDDD
Data size:
16-bit
Z
PR triggered by EV3 falling-edge
U
PR triggered by EV4 falling-edge