Delta ASDA-A3 Series User Manual page 355

Hide thumbs Also See for ASDA-A3 Series:
Table of Contents

Advertisement

Parameters
P3.006
Default:
8
Unit:
Format:
Settings:
Source of the DI that controls the switch. Each bit of this parameter determines one input source of
DI signal:
Bit0 – Bit9 correspond to DI1 – DI10. Bit10 – Bit12 correspond to VDI11 – VDI13.
The setting of bit is as follows:
0: DI status is controlled by the external hardware.
1: DI status is controlled by P4.007.
For more information on DI, please see:
DI1 – DI8: P2.010 – P2.017
DI9 – DI10: P2.036 – P2.037
VDI11 – VDI13: P2.038 – P2.040
P3.007
Default:
Unit:
Format:
Settings:
Delay the time of communication response from servo drive to controller.
P3.008
P3.009
Default:
Unit:
Format:
Settings:
The synchronous setting is divided into E, T, D, and M (hexadecimal):
Digit
Function
Range
8-98
Digital input (DI) control switch
0x0
-
HEX
Communication response delay time
0
0.5 ms
DEC
Reserved
Communication synchronization
0x5055 (CANopen)
0x3511 (DMCNET)
-
HEX
E
Range of
synchronous
Target value
error
1 – 9
0 – 9
Control mode: All
Setting range: 0x0000 – 0x1FFF
Data size:
Control mode: All
Setting range: 0 – 1000
Data size:
Control mode: CANopen / DMCNET
Setting range: Shown as below
Data size:
T
D
Deadband
0 – F
Address: 030CH
030DH
16-bit
Address: 030EH
030FH
16-bit
Address: 0312H
0313H
16-bit
M
-
-
Revision December, 2017
ASDA-A3

Hide quick links:

Advertisement

Table of Contents
loading