Parameters
P0.035
Default:
8
Unit:
Format:
Settings:
The formats of the high-bit parameter (PH) and the low-bit parameter (PL) are:
BA
C
D
h
Select the data block to access the parameter correspondingto register 1. The mapping value is
32 bits and can map to two 16-bit parameters or one 32-bit parameter.
P0.035: (Mapping parameter: P0.035; Mapping content: P0.025)
1.
When PH does not equal PL, it indicates that the content of P0.025 includes two 16-bit parameters.
Example: Target: set P2.003 to 0 in the mapping parameter and set P2.005 to 100.
8-20
Target setting for mapping parameter P0.025
-
-
HEX
D
C
BA
Hexadecimal code for the parameter
index
Hexadecimal code for the parameter
group
N/A
High-bit
Set the P parameter
.
P0
035
Map the P parameter
value set by P0.035
P0. 025
Setting: set the P0.035 high bit to 0203 (P2.003) and low bit to 0205 (P2.005).
Thus, P0.035 = 0x02030205.
P0.035
Write: in the mapping content, set P0.025 to 0x00050064, and the values of P2.003 and
P2.005 are:
P 0. 025
P2.003
Control mode: All
Setting range: Determined by the communication
Data size:
Hexadecimal code for the parameter
YX
index
Hexadecimal code for the parameter
Z
group
U
N/A
L
Low-bit
Set the P parameter
to be mapped for
to be mapped for
P0.025 high bit
P0.025 low bit
Map the P parameter
value set by P0.035
high bit
low bit
P2.003
P2.005
0005
0064
P2.005
0005
Address: 0046H
0047H
address of the parameter group
32-bit
U
Z
YX
0064