Parameters
P5.093
Default:
8
Unit:
Format:
Settings:
Before executing the macro command, you must set the relevant parameter #4 in advance.
The function of the parameter is determined by the macro command. Not every macro command
requires this parameter.
Note: A3-L does not support the E-Cam function and macros with E-Cam settings.
P5.094
Default:
Unit:
Format:
Settings:
Before executing the macro command, you must set the relevant parameter #3 in advance.
The function of the parameter is determined by the macro command. Not every macro command
requires this parameter.
Note: A3-L does not support the E-Cam function and macros with E-Cam settings.
P5.095
Default:
Unit:
Format:
Settings:
Before executing the macro command, you must set the relevant parameter #2 in advance.
The function of the parameter is determined by the macro command. Not every macro command
requires this parameter.
Note: A3-L does not support the E-Cam function and macros with E-Cam settings.
P5.096
Default:
Unit:
Format:
8-138
Motion control macro command: command parameter #4
0
-
HEX
Motion control macro command: command parameter #3
0
-
DEC
Motion control macro command: command parameter #2
0
-
DEC
Motion control macro command: command parameter #1
0
-
DEC
Control mode: All
Setting range: 0x00000000 – 0xFFFFFFFF
Data size:
32-bit
Control mode: All
Setting range: -2147483648 to +2147483647
Data size:
32-bit
Control mode: All
Setting range: -2147483648 to +2147483647
Data size:
32-bit
Control mode: All
Setting range: -2147483648 to +2147483647
Data size:
32-bit
ASDA-A3
Address: 05BAH
05BBH
Address: 05BCH
05BDH
Address: 05BEH
05BFH
Address: 05C0H
05C1H
Revision December, 2017