Note:
1.
After the origin is found (sensor or Z), it has to decelerate to a stop. The stop position exceeds the origin by a
short distance:
If returning to the origin is not needed, set PATH to 0;
If returning to the origin is needed, set PATH to a non-zero value and set PABS = ORG_DEF.
Example:
Upon completion of P6.000 = 0x1, automatically execute Path#1.
Set from absolute position (ABS) to 0 as the route of Path#1 (set P6.002 & P6.003).
2.
If the origin is found (sensor or Z), and you want it to move an offset S and define the coordinate as P after moving,
then PATH = non-zero and set ORG_DEF = P - S, and this absolute Position command = P.
P6.001
Default:
0
Unit:
-
Format:
DEC
Settings:
Origin definition.
P6.002
Default:
0x00000000
Unit:
-
Format:
HEX
Settings:
Format of this parameter: (High word h) DCBA : (Low word L) UZYX
A
SPD, Target speed index*
B
DLY, Delay time index
C
AUTO*
D
Reserved
Revision December, 2017
Origin definition
PATH#1 definition
High word
D
C
B A
1
1
Control mode: PR
Setting range: -2147483648 to +2147483647
Data size:
32-bit
Control mode: PR
Setting range: 0x00000000 – 0xFFFFFFFF
Data size:
32-bit
Low word
U
Z
X
TYPE, Path type
Y
OPT, Option
Z
ACC, Acceleration time index*
U
DEC, Deceleration time index*
Parameters
Address: 0602H
0603H
Address: 0604H
0605H
Y
X
1
1
8-151
8