ASDA-A3

Motion control type:

AL207 Parameter group of PR#8 is out of range
Trigger condition
and causes
Checking methods
and corrective
actions
How to clear the
alarm?
AL209 Parameter number of PR#8 is out of range
Trigger condition
and causes
Checking methods
and corrective
actions
How to clear the
alarm?
AL213 Parameter setting of PR#8 is in error
Trigger condition
and causes
Checking methods
and corrective
actions
How to clear the
alarm?
AL215 Write parameters: read-only
Trigger condition
and causes
Checking methods
and corrective
actions
How to clear the
alarm?
Revision December, 2017
Condition: parameter group for PR#8, P_Group, is out of range.
Cause: the group for PR#8 command source exceeds the range.
Writing parameter using PR procedure: the parameter group of command
source exceeds the range. Please check the setting.
DI.ARST or set P0.001 to 0.
Condition: parameter number for PR#8 is out of range.
Cause: parameter number is out of range.
Writing parameter using PR procedure: parameter number of PR#8 is out of
range. Please check the setting.
DI.ARST or set P0.001 to 0.
Condition: when using PR#8 to write parameters, the parameter value is
incorrect.
Cause: parameter value of PR#8 is in error.
Make sure the parameter value is within the correct range.
DI.ARST or set P0.001 to 0.
Condition: write parameters using PR procedure: the parameter is
read-only.
Cause: an error occurs when writing parameters with PR#8 command.
The specified parameter is read-only.
DI.ARST or set P0.001 to 0.