ASDA-A3
P2.069●
Default:
0x0000
Unit:
-
Format:
HEX
Settings:
U
Z
Y
X
Set up operation mode
Y: Pulse command setting when
Y
absolute position is lost
X: set up operation mode
0: Incremental type; an absolute type motor can be operated as an incremental type
1: Absolute type. This setting is only applicable to an absolute type motor. If it is used on an
incremental type motor, AL069 occurs.
Y: Pulse command setting when absolute position is lost
0: when AL060 or AL06A occurs, the system cannot accept a pulse command.
1: when AL060 or AL06A occurs, the system can accept a pulse command.
Z: index coordinates function when an overflow occurs
0: index coordinates are lost when an overflow occurs.
1: index coordinates are not affected by overflow, but absolute coordinates are not retained.
U: reserved
Note:
1. This function is coming soon.
2. Changes to this setting are effective only after power is cycled to the servo drive.
P2.070
Default:
0x0000
Unit:
-
Format:
HEX
Settings:
7
6
Bit
15
14
Bit
Revision December, 2017
Absolute encoder
X
Read data selection
5
4
3
2
1
13
12
11
10
9
Control mode: All
Setting range: 0 – 1
Data size:
16-bit
Index coordinates function setting
Z
when overflow occurs
U
Reserved
Control mode: All
Setting range: 0x00 – 0x07
Data size:
16-bit
0
8
Parameters
Address: 028AH
028BH
Address: 028CH
028DH
8-83
8