Parameters
P0.053
Default:
8
Unit:
Format:
Settings:
U
X: first filter time
Y – U: reserved
Example of the first filter:
P0.054
Default:
Unit:
Format:
Settings:
Whenever the value of P0.009 changes from outside the set range to inside the set range or vice versa,
it displays, but only after the filter time set in P0.053.X.
P0.055
Default:
Unit:
Format:
Settings:
Whenever the value of P0.009 changes from outside the set range to inside the set range or vice versa,
it displays, but only after the filter time set by P0.053.X.
8-26
General range compare DO output - Filter time
0x0000
ms
HEX
Z
Y
X
P0.055
P0.054
P0.009 monitoring
item value
On
Digital
Output Off
General range compare DO output - First lower limit
0
-
DEC
General range compare DO output - First upper limit
0
-
DEC
Control mode: All
Setting range: 0x0000 – 0x000F
Data size:
16-bit
P0.053.X
filtering
time
Control mode: All
Setting range: -2147483648 to +2147483647
Data size:
32-bit
Control mode: All
Setting range: -2147483648 to +2147483647
Data size:
32-bit
ASDA-A3
Address: 006AH
006BH
Address: 006CH
006DH
Address: 006EH
006FH
Revision December, 2017