ASDA-A3
P1.029
Default:
0
Unit:
-
Format:
DEC
Settings:
0: disable the automatic low-frequency vibration detection function.
1: disable the function automatically after vibration suppression. The value resets to 0 automatically.
Auto mode setting description:
When the value is 1, vibration suppression is in automatic mode. When the vibration cannot be detected
or the vibration frequency is stable, the system resets the parameter to 0 and automatically saves the
vibration suppression frequency to P1.025.
P1.030
Default:
800
Unit:
Pulse
Format:
DEC
Settings:
When enabling automatic vibration suppression (P1.029 = 1), the system automatically finds the
detection level. The lower the value, the more sensitive the detection, but the system may also misjudge
noise or treat other low-frequency vibrations as frequencies to be suppressed. If the value is high, the
system is less likely to misjudge, but if the vibration of the machine is small, the system may not properly
detect low-frequency vibrations.
P1.031
P1.032
Default:
0x0000
Unit:
-
Format:
HEX
Settings:
U
Z
Y
X
Reserved
Revision December, 2017
Auto low-frequency vibration suppression mode
Low-frequency vibration detection
Reserved
Motor stop mode
X
Y
Dynamic brake operation options
Control mode: PT / PR
Setting range: 0 – 1
Data size:
16-bit
Control mode: PT / PR
Setting range: 1 – 8000
Data size:
16-bit
Control mode: All
Setting range: 0 – 20
Data size:
16-bit
Parameters
Address: 013AH
013BH
Address: 013CH
013DH
Address: 0140H
0141H
UZ
Reserved
8-41
8