ASDA-A3
W
P6.000
Homing definition
Default:
0x00000000
Unit:
-
Format:
HEX
Settings:
Homing definition:
D
C
B
DEC2: deceleration time selection of
A
second homing
B
DLY: select 0 – F for delay time
C
N/A
D
BOOT
YX: PATH: path type
0x0: stop: homing complete and stop.
0x1 – 0x63: auto: homing complete and execute the specified path (Path#1 – Path#99).
Z: ACC: select 0 – F for acceleration time
0 – F: corresponds to P5.020 – P5.035
U: DEC1: deceleration time selection of first homing
0 – F: corresponds to P5.020 – P5.035
A: DEC2: deceleration time selection of second homing
0 – F: corresponds to P5.020 – P5.035
B: DLY: select 0 – F for delay time
0 – F: corresponds to P5.040 – P5.055
Revision December, 2017
Z
A
Y
X = 5: look for Z pulse in
reverse direction and
define it as homing
origin
X = 6: homing in
forward direction, ORG:
ONOFF as homing
origin
X = 7: homing in
reverse direction, ORG:
ONOFF as homing
origin
X = 8: define current
position as the origin
X = 9: look for the
Y = 0: return to Z pulse
collision point in forward
Y = 1: do not look for
direction and define it
Z pulse
as the origin
X = A: look for the
collision point in reverse
direction and define it
as the origin
Control mode: PR
Setting range: 0x00000000 – 0xFFFFFF3F
Data size:
32-bit
U
Z
YX
YX
PATH: path type
Z
ACC: select 0 – F for acceleration time
DEC1: deceleration time selection of
U
first homing
-
-
Motion Control
X
Address: 0600H
0601H
7
7-9