Troubleshooting
AL123 Data size error occurs when CANopen PDO is received
Trigger condition
11
and causes
Checking methods
and corrective
actions
How to clear the
alarm?
AL124 Data range error occurs when CANopen PDO is received
Trigger condition
and causes
Checking methods
and corrective
actions
How to clear the
alarm?
AL125 CANopen object is read-only and write-protected
Trigger condition
and causes
Checking methods
and corrective
actions
How to clear the
alarm?
AL126 Specified object does not support PDO mapping
Trigger condition
and causes
Checking methods
and corrective
actions
How to clear the
alarm?
AL127 CANopen PDO is write-protected when servo drive is on
Trigger condition
and causes
Checking methods
and corrective
actions
How to clear the
alarm?
11-34
Data length in the message does not match the length of the specified
object.
Check if the data length for PDO mapping is changed when the servo drive
receives or sends PDO.
NMT: reset node or 0x6040 (fault reset).
The data value in the message is out of range for the specified object.
Check if the written range is wrong when the servo drive receives or sends
PDO.
NMT: reset node or 0x6040 (fault reset).
The specified object in the message is read-only and write-protected.
Check if the object for the PDO mapping is read-only.
NMT: reset node or 0x6040 (fault reset).
The specified object in the message does not support PDO mapping.
Check if the specified object allows PDO mapping when PDO is receiving
or sending.
NMT: reset node or 0x6040 (fault reset).
The specified object in the message is write-protected when the servo drive is
on.
Make sure no PDO is written when servo drive is on.
NMT: reset node or 0x6040 (fault reset).