Command Line Interface Reference Guide
Example: power-over-ethernet threshold option
Executing the following command sets the global notification threshold to 70% of available PoE
power:
ProCurve(config)# power-over-ethernet threshold 70

COMMAND DETAILS

pre-std-detect (p. 404)
redundancy (p. 404)
pre-std-detect
■ [no] power-over-ethernet pre-std-detect
Usage: [NO] power-over-ethernet pre-std-detect
Description: Detect and power pre-802.3af-standard devices. This is enabled
by default.
redundancy
■ [no] power-over-ethernet redundancy
Usage: [NO] power redundancy [n+1|full]
Description: Set how much power is held in reserve for redundancy.
Next Available Option:
redundancy_type
(NUMBER)
redundancy_type
■ power-over-ethernet redundancy < n+1 | full >
Usage: [NO] power redundancy [n+1|full]
Description: Set how much power is held in reserve for redundancy.
Supported Values:
■ n+1
© 2009 Hewlett-Packard Development Company, L.P.
redundancy_type (p. 404)
slot (p. 405)
NO
- All available power can be allocated to powered devices.
n+1
- One of the highest power supplies will be held in
reserve. In the event of a simgle power supply failure,
no powered devices will be shut down.
full - Half of the available power supplies will be held in
reserve.
Default: No PoE redundancy enforced.
< n+1 | full > -- Set how much power is held in reserve for redundancy
(p. 404)
NO
- All available power can be allocated to powered devices.
n+1
- One of the highest power supplies will be held in
reserve. In the event of a simgle power supply failure,
no powered devices will be shut down.
full - Half of the available power supplies will be held in
reserve.
power-over-ethernet
threshold (p. 405)
404

Advertisement

Table of Contents
loading

This manual is also suitable for:

Procurve 3500ylProcurve 8200zl6200yl

Table of Contents