Panasonic FP-E Programming Manual page 174

Fp series
Table of Contents

Advertisement

Basic Instructions
LOOP
LBL
Outline
Skips to the LBL instruction that has the same number as the LOOP
instruction and executes what follows, repeatedly, until the data of a
specified operand becomes "0".
Program example
10
16
30
S
Operands
Relay
Instruction
Instruction
WX WY WR
Set value
N/A
A
(*1) This cannot be used with the FP0/FP−e.
(*2) This cannot be used with the FP0/FP−e/FP0R/FPΣ/FP−X.
(*3) With the FP0R, FPΣ, FP−X, FP2, FP2SH and FP10SH, this is I0 to IC.
(*4) With the FP0R, FPΣ, FP−X, FP2, FP2SH and FP10SH, this is ID.
(*5) Only FP2, FP2SH and FP10SH label numbers can be used.
2 − 64
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Loop
Label
Ladder Diagram
Ladder Diagram
X0
F0 MV, K5, DT 0
Label number
Number of timers for loop
X1
LOOP 1 , DT 0
Label number
16-bit area for setting number of times for loop operation
Timer/Counter
WL
SV
EV
(*1)
A
A
A
A
7
(LBL 1 )
S
Index
Register
register
LD
FL
IX
IY
DT
(*1)
(*2)
(*3)
(*4)
A
A
A
A
A
Boolean
Address
Instruction
10
ST
X
11
F0
K
DT
16
LBL
30
ST
X
31
LOOP
DT
Constant
Index
modifier
modifier
(*5)
K
H
N/A
N/A
A
A:
Available
N/A: Not Available
0
(MV)
5
0
1
1
1
0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fp0Fp2Fp2shFp0rFrsFp10sh ... Show all

Table of Contents