S-Rdy (Servo Ready Output) Signal; Bk (Brake Output) Signal - YASKAWA SGD7S-xxxDA0 series Product Manual

S-7-series ac servo drive; s-7s servopack with 400v-input power and ethercat (coe) communications references
Table of Contents

Advertisement

12.2.8

/S-RDY (Servo Ready Output) Signal

The Servo ON command (Enable Operation command) will not be acknowledged in the HWBB
state. Therefore, the Servo Ready Output Signal will turn OFF. The Servo Ready Output Signal
will turn ON if both the /HWBB1 and /HWBB2 signals are ON and the servo is turned OFF (BB
state).
An example is provided below for when the main circuit power supply is ON when there is no
servo alarm.
/HWBB1
/HWBB2
Controlword (6040h)
SERVOPACK
Status
/S-RDY (Servo
Ready Output
Signal)
12.2.9

/BK (Brake Output) Signal

If the HWBB operates when the /HWBB1 or /HWBB2 signal is OFF, the /BK (Brake) signal will
turn OFF. At that time, the setting in Pn506 (Brake Reference - Servo OFF Delay Time) will be
disabled. Therefore, the Servomotor may be moved by external force until the actual brake
becomes effective after the /BK signal turns OFF.
 The brake signal is not a safety-related element. You must design the system so that a haz-
ardous condition does not occur even if the brake signal fails in the HWBB state. Also, if a
Servomotor with a Brake is used, keep in mind that the brake in the Servomotor is used only
to prevent the moving part from being moved by gravity or an external force and it cannot
be used to stop the Servomotor.
OFF (motor current
ON (normal
shut-OFF request)
operation)
Enable
Operation
Operating
HWBB state
Status
OFF
ON
12.2 Hard Wire Base Block (HWBB and SBB)

12.2.8 /S-RDY (Servo Ready Output) Signal

ON (normal
operation)
Shutdown
BB state
ON
CAUTION
12
12-9

Advertisement

Table of Contents
loading

Table of Contents