YASKAWA SGD7S-xxxDA0 series Product Manual page 259

S-7-series ac servo drive; s-7s servopack with 400v-input power and ethercat (coe) communications references
Table of Contents

Advertisement

7.15 Overheat Protection
7.15.2 Overheat Protection Selections
Using Overheat Protection in the Yaskawa Linear Servomo-
tor
To use the overheat protection in a Yaskawa Linear Servomotor (SGLFW2), set Pn61A to
n.1.
An A.93B warning (Overheat Warning) will be detected if the overheat protection input (TH) sig-
nal from the Yaskawa SGLFW2 Linear Servomotor exceeds the warning temperature.
An A.862 alarm (Overheat Alarm) will be detected if the overheat protection input (TH) signal
from the Yaskawa SGLFW2 Linear Servomotor exceeds the alarm temperature.
Important
Monitoring the Machine's Temperature and Using Overheat
Protection
Set Pn61A = n.X to 2 or 3 to use overheat protection for the machine.
Set the following parameters as required.
Pn61B
(261Bh)
Pn61C
(261Ch)
Pn61D
(261Dh)
Important
7-64
• If the overheat protection input signal line is disconnected or short-circuited, an A.862 alarm
will occur.
• If you set Pn61A to n.1 (Use overheat protection in the Yaskawa Linear Servomotor), the
parameters in the Servomotor are enabled and the following parameters are disabled.
• Overheat Alarm Level (Pn61B)
• Overheat Warning Level (Pn61C)
• Overheat Alarm Filter Time (Pn61D)
Overheat Alarm Level
Setting Range
Setting Unit
0 to 500
Overheat Warning Level
Setting Range
Setting Unit
0 to 100
Overheat Alarm Filter Time
Setting Range
Setting Unit
0 to 65,535
• When Pn61A is set to n.2, an A.862 alarm will occur if the overheat protection input sig-
nal line is disconnected or short-circuited.
• When Pn61A is set to n.3, an A.862 alarm will not occur if the overheat protection input
signal line is disconnected or short-circuited. To ensure safety, we recommend that you con-
nect the external circuits so that you can use a negative voltage input for the overheat protec-
tion input (an analog voltage input).
Default Setting
0.01 V
250
Default Setting
1%
100
Default Setting
1 s
0
Speed
Position
Torque
When Enabled
Classification
Immediately
Setup
Speed
Position
Torque
When Enabled
Classification
Immediately
Setup
Speed
Position
Torque
When Enabled
Classification
Immediately
Setup

Advertisement