Sync Manager Communications Objects - YASKAWA SGD7S-xxxDA0 series Product Manual

S-7-series ac servo drive; s-7s servopack with 400v-input power and ethercat (coe) communications references
Table of Contents

Advertisement

15.4

Sync Manager Communications Objects

Sync Manager Communications Type (1C00h)
Subin-
Index
dex
0
1
1C00h
2
3
4
Sync Manager PDO Assignment (1C10h to 1C13h)
This object defines which PDOs will be transferred in the process data communications.
Subin-
Index
dex
1C10h
0
1C11h
0
0
1
1C12h
2
0
1
1C13h
2
Objects 1C12h and 1C13h can be changed when the EtherCAT (CoE) Network Module is in the
Pre-Operational state. Set subindex 1 or 2 only after you write 0 to subindex 0.
Data
Name
Type
Number of
used Sync Manager
USINT
channels
Communication type
USINT
sync manager 0
Communication type
USINT
sync manager 1
Communication type
USINT
sync manager 2
Communication type
USINT
sync manager 3
Data
Name
Type
Sync manager PDO
USINT
assignment 0
Sync manager PDO
USINT
assignment 1
Number of assigned
USINT
PDOs
Index of assigned
UINT
RxPDO 1
Index of assigned
UINT
RxPDO 2
Number of assigned
USINT
PDOs
Index of assigned
UINT
TxPDO 1
Index of assigned
UINT
TxPDO 2

15.4 Sync Manager Communications Objects

PDO
Access
Mapping
RO
No
4
1: Mailbox recep-
RO
No
tion
(master to slave)
2: Mailbox send
RO
No
(slave to master)
3: Process data
RO
No
output
(master to slave)
4: Process data
RO
No
input
(slave to master)
PDO
Access
Mapping
RO
No
RO
No
RW
No
0 to 2 (default: 1)
1600h to
RW
No
(default: 1601h)
1600h to
RW
No
(default: 1600h)
RW
No
0 to 2 (default: 1)
1A00h to
RW
No
(default: 1A01h)
1A00h to
RW
No
(default: 1A00h)
Saving to
Value
EEPROM
No
No
No
No
No
Saving to
Value
EEPROM
0
No
0
No
Yes
1603h
Yes
1603h
Yes
Yes
1A03h
Yes
1A03h
Yes
15-13