Mounting Interval; Installing One Servopack In A Control Panel; Installing More Than One Servopack In A Control Panel - YASKAWA SGD7S-xxxDA0 series Product Manual

S-7-series ac servo drive; s-7s servopack with 400v-input power and ethercat (coe) communications references
Table of Contents

Advertisement

3.4

Mounting Interval

3.4.1

Installing One SERVOPACK in a Control Panel

Provide the following spaces around the SERVOPACK.
120 mm min.
30 mm min.
*
For this dimension, ignore items protruding from the main body of the SERVOPACK.
3.4.2
Installing More Than One SERVOPACK in a Control
Panel
Provide the following spaces around the SERVOPACK, and install a cooling fan in the control
panel.
Install cooling fans above the SERVOPACKs so that hot spots do not occur around the SERVO-
PACKs.
Important
120 mm min.
SERVOPACK model
1R9D, 3R5D, 5R4D,
SGD7S-
8R4D, 120D, 170D,
210D, 260D, 280D, 370D
30 mm min.
120 mm min.*
Fan
Fan
30 mm min.
Cooling Fan Installation Conditions
10 mm above SERVOPACK's Top Surface
Air speed: 1.0 m/s min.

3.4.1 Installing One SERVOPACK in a Control Panel

30 mm min.
120 mm min.

3.4 Mounting Interval