17.1 List of Parameters
17.1.2 List of Parameters
Parameter
No.
Pn512
(2512h)
Pn513
(2513h)
Pn514
(2514h)
17-26
Name
Output Signal Inverse
2
Settings 1
Output Signal Inversion for CN1-1 and CN1-2 Terminals
n.
X
0
The signal is not inverted.
1
The signal is inverted.
Output Signal Inversion for CN1-23 and CN1-24 Terminals
n.
X
0
The signal is not inverted.
1
The signal is inverted.
Output Signal Inversion for CN1-25 and CN1-26 Terminals
n.
X
0
The signal is not inverted.
1
The signal is inverted.
Output Signal Inversion for CN1-27 and CN1-28 Terminals
n.X
0
The signal is not inverted.
1
The signal is inverted.
Output Signal Inverse
2
Settings 2
Output Signal Inversion for CN1-29 and CN1-30 Terminals
n.
X
0
The signal is not inverted.
1
The signal is inverted.
n.
X
Reserved parameter (Do not change.)
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
Output Signal Selec-
2
tions 4
n.
X
Reserved parameter (Do not change.)
n.
X
Reserved parameter (Do not change.)
/PM (Preventative Maintenance Output) Signal Allocation
0
Disabled (the above signal output is not used).
1
Output the signal from the CN1-1 or CN1-2 output terminal.
2
Output the signal from the CN1-23 or CN1-24 output terminal.
n.
X
3
Output the signal from the CN1-25 or CN1-26 output terminal.
4
Output the signal from the CN1-27 or CN1-28 output terminal.
5
Output the signal from the CN1-29 or CN1-30 output terminal.
6
Reserved setting (Do not use.)
n.X
Reserved parameter (Do not change.)
Setting
Setting
Default
Range
Unit
Setting
0000h to
–
0000h
1111h
0000h to
–
0000h
0011h
0000h to
–
0000h
0666h
Continued from previous page.
Applicable
When
Classi-
Motors
Enabled
fication
After
All
Setup
restart
After
All
Setup
restart
Reference
page 6-23
After
All
Setup
restart
Reference
page 10-
Continued on next page.
Refer-
ence
page
7-5
page
7-5
–
15