Warning Number
Warning Name
Position Deviation
A.901
Overflow Warning at
Servo ON

9.3.5 Setting the Position Deviation Overflow Alarm Level at Servo ON

Warning Meaning
This warning occurs if the servo is turned ON while the position
deviation exceeds the specified percentage (Pn526 × Pn528/100).