YASKAWA SGD7S-xxxDA0 series Product Manual page 530

S-7-series ac servo drive; s-7s servopack with 400v-input power and ethercat (coe) communications references
Table of Contents

Advertisement

16.2 Alarm Displays
16.2.2 Troubleshooting Alarms
Alarm Code:
Alarm Name
850h:
Encoder Over-
speed
(Detected at the
encoder when
the control power
supply is turned
ON.)
860h:
Encoder Over-
heated
(Detected at the
encoder, but only
when an abso-
lute encoder is
used.)
16-24
Possible Cause
Rotary Servomotor:
The Servomotor
Check the motor speed
-1
speed was 200 min
when the power supply
or higher when the
is turned ON.
control power supply
was turned ON.
Linear Servomotor:
The Servomotor
Check the motor speed
exceeded the speci-
when the power supply
fied speed when the
is turned ON.
control power supply
was turned ON.
A failure occurred in
the encoder.
A failure occurred in
the SERVOPACK.
The surrounding air
Measure the surround-
temperature around
ing air temperature
the Servomotor is too
around the Servomotor.
high.
The Servomotor load
Use the accumulated
is greater than the
load ratio to check the
rated load.
load.
A failure occurred in
the encoder.
A failure occurred in
the SERVOPACK.
Confirmation
Reduce the Servomotor
speed to a value less than
200 min
the control power supply.
Control the motor speed
within the range specified
by the linear encoder
manufacturer and then
turn ON the control power
supply.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the Servomotor or
linear encoder may be
faulty. Replace the Servo-
motor or linear encoder.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
Reduce the surrounding
air temperature of the
Servomotor to 40°C or
less.
Operate the Servo Drive
so that the motor load
remains within the speci-
fied range.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the Servomotor or
absolute linear encoder
may be faulty. Replace the
Servomotor or absolute
linear encoder.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
Continued from previous page.
Correction
Reference
-1
, and turn ON
page 10-3
Continued on next page.