Alarm Code:
Possible Cause
Alarm Name
The servo was turned
ON after the position
d01h:
deviation exceeded
the setting of Pn526
Position Devia-
(2526h) (Excessive
tion Overflow
Position Deviation
Alarm at Servo
Alarm Level at Servo
ON
ON) while the servo
was OFF.
If position deviation
remains in the devia-
tion counter, the set-
ting of Pn529 (2529h)
or Pn584 (2584h)
(Speed Limit Level at
d02h:
Servo ON) limits the
Position Devia-
speed when the servo
tion Overflow
is turned ON. This
Alarm for Speed
alarm occurs if a posi-
Limit at Servo ON
tion reference is input
and the setting of
Pn520 (2520h)
(Excessive Position
Deviation Alarm Level)
is exceeded.
The motor direction
and external encoder
installation orientation
d10h:
are backward.
Motor-Load Posi-
tion Deviation
Overflow
There is an error in the
connection between
the load (e.g., stage)
and external encoder
coupling.
d30h:
The position data
Position Data
exceeded
±1,879,048,192.
Overflow
E00h:
EtherCAT Module
A failure occurred in
the SERVOPACK.
Interface Initializa-
tion Timeout Error
The EtherCAT trans-
mission cycle fluctu-
ated.
E02h:
EtherCAT Inter-
nal Synchroniza-
tion Error 1
A failure occurred in
the SERVOPACK.
Noise caused an error
in communications
E03h:
between the SERVO-
EtherCAT Mod-
PACK and EtherCAT
ule Interface
Network Module.
Communications
Data Error
A failure occurred in
the SERVOPACK.
Confirmation
Check the position
Optimize the setting of
deviation while the
Pn526 (2526h).
servo is OFF.
Optimize the setting of
Pn520 (2520h). Or, set
Pn529 (2529h) or Pn584
(2584h) to an appropriate
value.
Install the external
encoder in the opposite
Check the motor direc-
direction, or change the
tion and the external
setting of Pn002 (2002h)
encoder installation ori-
= n.X (External
entation.
Encoder Usage) to
reverse the direction.
Check the coupling of
Check the mechanical
the external encoder.
coupling.
Check the input refer-
Reconsider the operating
ence pulse counter.
specifications.
Replace the SERVO-
PACK.
Remove the cause of
transmission cycle fluctu-
ation at the host control-
ler.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
Implement countermea-
sures against noise.
Replace the SERVO-
PACK.
16.2 Alarm Displays
16.2.2 Troubleshooting Alarms
Continued from previous page.
Correction
Reference
page 9-8
page 11-6
Continued on next page.