7.10.11.2 Copying using the PC control software

Parameter values can be saved on standard digital memory cards (Bonfiglioli Vectron "Resource
Pack") using the PC control software VPlus and uploaded on a frequency inverter.
Activate in the Saving mask for the usage on a MMC card always the function "Save to Multimedia
Card". To save a file for a MMC card only file names in the range from 0001 to 9999 are allowed to be
used. The file names must be entered in the format "four-digit" + file extension for the usage on a
MMC card.
Please note, that when storing via VPlus always the parameters of the selected control
level are stored. Bonfiglioli Vectron recommends to read out the frequency inverter in
control level 3 in VPlus before storing the file.
7.10.12

Converter Profibus from/to Internal Notation

1370 In-F-PDP-word 1
1371 In-F-PDP-word 2
1372 In-F-intern-long 1
1373 In-F-intern-long 2
1374 In-F-Convert Reference
The Converter Profibus/Internal notation can convert a 16 bit Word into an internal 32 Bit frequency
value and vice versa. This is useful in example, when several devices are linked together via System-
bus and for commercial reasons only one device is equipped with a Profibus Option. Through the rout-
ing of the Profibus Word via the Systembus ("Tunneling") the necessary bandwidth can be reduced
and the parameterization of the "Gateway" (Systembus Master with Profibus Slave communication) be
simplified. The converter is used in this case in a device without Profibus module to convert the Profi-
bus Notation into an internal reference value.
A similar procedure can be used to convert in example the Actual Frequency into a value according to
Profibus notation.
The converter can also be used for other purposes, in example when using the internal PLC program-
ming.
1370 and
In-F-PDP-word 1
Frequency. 0x4000 in Profibus-Notation (=100 %) refers to
1372 and
In-F-intern-long 1
bus Notation. 0x4000 in Profibus-Notation (=100 %) refers to
The Profibus Notation is limited to values from -200 % (0x8000) to +200 % (0x7FFF).
0x4000
= 100 %
0x7FFF
= 200 %
0x8000
= -200 %
0xC000
= -100 %
The values converted this way can be used as internal source.
774 – Out-F-PDP-Conv1-long1 as output of
775 – Out-F-PDP-Conv1-long2 as output of
776 – Out-F-PDP-Conv1-word1 as output of
777 – Out-F-PDP-Conv2-word2 as output of
Agile
Operating Instructions
VPlus
SAVE
1371 convert the Profibus Notation into the internal
In-F-PDP-word 2
1373 convert an internal frequency value into Profi-
In-F-intern-long 2
=
In-F-Convert Reference
=
2x In-F-Convert Reference
= -
2x In-F-Convert Reference
= -
In-F-Convert Reference
In-F-PDP-word 1
In-F-PDP-word 2
In-F-PDP-long 1
In-F-PDP-long 2
256
06/2013
Parameter descriptions
LOAD
In-F-Convert Reference
In-F-Convert Reference
1374
1374
1374
1374
1370 (Profibus-Not.  Frequency)
1371 (Profibus-Not.  Frequency)
1372 (Frequency  Profibus-Not.)
1373 (Frequency  Profibus-Not.)
1374 in Hz.
1374 in Hz.
Special functions

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents