Commissioning
Electronic gear
Synchronization of drives.
Reference
Set P496 to "20 - repetition frequency single evaluation:" or "21 - Rep-
value for
etition frequency double evaluation". IN2D (X11.5) is the frequency
slave drive
input.
Set P497 (typically identical to P556 of the master drive).
Switch on
Set P475 or P492 to "40 - electr. gear".
Gear factor
Fixed
Variable
Master drive
Output MFO1: Set P550 to "20 - Repetition Frequency MFO1F".
For P555, select a frequency source (1- Actual Frequency). Via P556,
set the output frequency.
Positioning
P458 to "1 - Reference positioning". The reference point is detected via
digital input IN1D (terminal X11.4).
In P460, enter the travel distance in motor revolutions.
PLC: Logic functions and functions with analog quantities
Via graphic functional block programming or via entries in a table,
analog quantities can be influences and logic links to digital signals can
be created.
1
Application manual "PLC".
Typical functions
Set P689 to "1 - (P. 685 Numerator)/(P. 686 Denomina-
tor)". Set P685 and P686.
Set P689 to "2 - (Analog Numerator)/(P. 686 Denominator)"
or "3 - (P. 685 Numerator)/(Analog Denominator)". Set the
range via P687 and P688.
For P476 or P494, select a signal source. Via the signal
source the gear factor can be changed during operation.