Warning Mask, Application - BONFIGLIOLI Agile Operating Instructions Manual

Frequency inverter 230 v / 400 0.09 kw ... 11 kw
Hide thumbs Also See for Agile:
Table of Contents

Advertisement

Parameter descriptions
Output signals
The output of a warning is signaled.
1)
157 - Warning
2)
mask
25 -
1)
For linking to frequency inverter functions.
2)
For output via a digital output. Select the signal source for one of the parameters 531, 532, 533,
554. See chapter 7.6.5 "Digital outputs".
Parameter
independent from the created Warning mask.
Parameter
show the Controller Status independent from the created Warning mask.
7.6.5.9

Warning mask, application

626 Create Warning Mask Application
The Warning mask Application signals via a digital signal if an afore configured warning applies. The
configuration of the Warning mask Application is carried out via
Depending on the application, any number of warnings can be configured. This enables internal
and/or external control using a common output signal. The display of
affected by the Warning mask.
Create Appl. Warning Mask
0 - No change
2 - Activate all warnings
10 - Warning V-belt
16 - Warning Service
17 - Warning User 1
18 - Warning User 2
102 - Deactivate all warnings
110 - Deactivate warning V-belt
116 - Deactivate warning service
117 - Deactivate warning User 1
118 - Deactivate warning User 2
The selected warning mask application can be read out via parameter
627. The above operation modes of parameter
Actual Appl. Warning Mask
operation modes and the corresponding abbreviation.
Warning code
A
01C1
-
A
0001
BELT
A
0040
SERVICE
A
0080
User 1
A
0100
User 2
Control inputs and outputs
Output of warning activated in
269 and
Warning
Warning
275 and
Controller Status
626
The configured warning mask is not changed.
The warnings reports stated are linked in the warning
mask.
Operation Mode
load operation of the application.
The time remaining until service of DC-link or fan has
expired.
The signal set on digital input
active.
The signal set on digital input
active.
All warnings are deactivated.
Warning 10 is deactivated.
Warning 16 is deactivated.
Warning 17 is deactivated.
Warning 18 is deactivated.
Create Appl. Warning Mask
627. The code is calculated by hexadecimal addition of the individual
Create Appl. Warning Mask
2 - Activate all warnings
10 - Warning V-belt
16 - Warning Service
17 - Warning User 1
18 - Warning User 2
195
Create Warning Mask
356 (error environment) show the warnings
355 (error environment)
Controller Status
Create Appl. Warning Mask
Warning Application
Function
581 for V-belt monitoring signals no-
User Warning 1
User Warning 2
Actual Appl. Warning Mask
626 are encoded in the
626
06/2013
Operating Instructions
536.
626.
273 is not
1363 is
1364 is
Agile