BONFIGLIOLI Agile Operating Instructions Manual page 266

Frequency inverter 230 v / 400 0.09 kw ... 11 kw
Hide thumbs Also See for Agile:
Table of Contents

Advertisement

No.
Description
252
Repetition frequency input
253
Analog input MFI2A
254
Digital outputs
255
Heat sink temperature
256
Inside temperature
257
Analog output MFO1A
258
PWM input
259
Actual Error
269
Warnings
273
Application Warnings
275
Controller Status
277
STO Status
278
Frequency MFO1F
282
Reference bus frequency
283
Reference ramp frequency Reference value from reference frequency channel.
470
Revolutions
1530 Service Interval DC-link
1531 Service Interval Fan
1533 Maintenance Note
1541 Status device test
The actual values can be read out and monitored in the "Actual" menu of the operator
panel.
Agile
Operating Instructions
Actual values of frequency inverter
Signal on repetition frequency input according to
496.
mode IN2D
Input signal at multifunction input 2. Via parameter
562, multifunction input 2 must be set up as a
mode MFI2
voltage or current input.
Status of digital outputs in decimally encoded form:
− of digital output OUT1D
− of multifunction output in setting
550 = "1 - Digital MFO1D"
(X13.6)
− of digital input/output in setting
558 = "1 - output OUT3D".
X11.6
− of relay output
Measured heat sink temperature. Warning or shutdown if tem-
perature is too high.
Measured inside temperature. Warning or shutdown if tempera-
ture is too high.
Output signal at multifunction output 1 in setting
mode MFO1 (X13.6)
Pulse-width modulated signal at PWM input according to
eration mode IN2D
Error message with error code and abbreviation. See chapter
13.1.1 "Error messages".
Warning message with warning code and abbreviation.
Please note:
Warnings
536.
mask
Warning message application with warning code and abbrevia-
tion. Please note:
Create warning mask
The reference value signal is limited by the controller coded in
the controller status.
Signal status of digital inputs A (STOA) and B (STOB) for ena-
ble.
Output signal at multifunction output in setting
550 = "20 - repetition frequency (FF) MFO1F"
MFO1 (X13.6)
or "30 - Pulse Train (PT) MFO1F".
Reference value from serial interface.
Actual value of position distance of positioning operation.
The time remaining until next service in percent of maintenance
interval. If a value of 0% is displayed, service is required. It
must also be checked if a component must be replaced. Refer
to chapter 10.3.1 "DC-link".
The time remaining until next service in percent of maintenance
interval. If a value of 0% is displayed, service is required. It
must also be checked if a component must be replaced. Refer
to chapter 10.3.2 "Fan".
Service status. Refer to chapter 10.3 "Monitoring of service
interval".
Service of device test. Refer to chapter 7.2.3 "Device test".
266
06/2013
Function
Operation mode MFO1
Operation modeterminal
550 = "10 - Analog (PWM) MFO1A"
496.
269 is not affected by
273 is not affected by
Warnings Application
626.
Actual values of frequency inverter
Actual values
Operation
Operation
Operation
Op-
Create warning
Operation mode