Parameter descriptions
Motor potentiometer via digital inputs Function
Percent Motorpoti
72
Up
0
1
0
1
0 = contact open
1 = contact closed
WARNING
If a negative reference value is set, the drive is decelerated with command "Percentage
motorpoti up". The reference value is changed in positive direction.
Limit
The reference values are limited via parameters
519.
Reference Percentage
Direction of rotation reversal
If parameter
Minimum Reference Percentage
can be reversed via the motorpoti function.
"Motorpotentiometer via digital inputs" as reference value
The function "Motorpotentiometer via digital inputs" can be selected via the following parameters:
Reference Percentage Source 1
Reference Percentage Source 2
See chapter 7.5.2 "Reference percentage channel".
Chapter 7.6.6.1 "List of control signals" contains a table summarizing the available signal sources for
parameters
Percent Motorpoti Up
Addition of reference values
If the reference value of the motorpoti function is added to another reference value, (via
476 plus
Percentage Source 1
− If the value of
Maximum Reference Percentage
increased, the output value of the motorpoti function is reduced. It is reduced, so that the sum of
both reference values is equal to the maximum reference percentage value.
− If the value of
Minimum Reference Percentage
reduced, the output value of the motorpoti function is increased. It is increased, so that the sum of
both reference values is equal to the minimum reference percentage value.
− In the settings for
Operation Mode
reversal of direction of rotation can be shifted by the output value of the motorpoti function. The
drive changes its direction of rotation if the total of the two reference values changes the sign.
Reference Values
Percent Motorpoti
73
Down
0
The reference percentage does not change.
0
The reference percentage increases at the set ramp.
The reference percentage decreases at the set
1
ramp.
The reference percentage is reset to the value of
Minimum Reference Percentage
reference percentage source is selected via parame-
1
ter
ence Percentage Source 2
quency is reset to the value of this source.
Minimum Reference Percentage
518 is set to zero, the direction of rotation of the drive
476
494
72 and
Percent Motorpoti Down
Reference Percentage Source 2
518 is reached and the other reference value is
495 = "1 - (+/-reference value)" or "3 - inverted", the point of
159
Reference Percentage Source 1
494, the reference fre-
73.
494):
519 is reached and the other reference value is
06/2013
Operating Instructions
518. If another
476 or
Refer-
518 and
Maximum
Reference
Agile