Actual values
No.
Description
295 Peak Value Active Power pos. Calculated maximum active power in motor operation.
Peak Value Active Power
296
neg.
297 Average Value Active Power
298 Peak Value Capacitor Temp.
Average Value Capacitor
299
Temp.
301 Energy, positive
302 Energy, negative
The actual values can be read out and monitored in the "Actual" menu of the operator
panel.
237 Reset Memory
Parameter
Reset Memory
and peak values. The mean value and the peak value are reset to zero.
237
Reset Memory
0 - No Reset
10 - Peak value long-term Ixt
12 - Peak value short-term Ixt Reset
20 - Peak value Vdc
21 - Average Value Vdc
30 - Peak value Tc
31 - Average Value Tc
32 - Peak value Ti
33 - Average Value Ti
Peak Value Capacitor
34 -
Temp.
Average Value Capacitor
35 -
Temp.
40 - Peak value Iabs.
41 - Average value Iabs
50 - Peak value Pactive pos.
52 - Peak value Pactive neg.
53 - Average value Pactive
54 - Energy, positive
56 - Energy, negative
100 - All peak values
101 - All average values
102 - All values
Actual value memory
Actual value memory
Calculated maximum active power in generator operation.
The mean active power calculated in the period of observation.
Maximum measured capacitor temperature.
The mean capacitor temperature calculated in the period of
observation.
The calculated energy to the motor in motor operation.
The calculated energy from the motor in generator operation.
237 in menu "Para" of the operator panel enables resetting of the mean
Values of actual value memory remain unchanged.
Reset
Peak Value Long Term Ixt
Peak Value Short Term Ixt
Reset
Peak Value Vdc
Reset
Average Value Vdc
Reset
Peak Value Heat Sink Temp.
Reset
Average Value Heat Sink Temp.
Reset
Peak Value Inside Temperature
Reset
Average Value Inside Temperature
Reset
Peak Value Capacitor Temp.
Reset
Average Value Capacitor Temp.
Reset
Peak Value Iabs
Reset
Average Value Iabs.
Reset
Peak Value Active Power pos.
Reset
Peak Value Active Power neg.
Reset
Average Value Active Power
Reset
Energy, positive
Reset
Energy, negative
Reset all saved peak values.
Reset all saved average values.
Reset whole actual value memory.
269
Function
Function
231.
232.
287.
288.
289.
290.
291.
292.
298.
299.
293.
294.
295.
296.
297.
301.
302.
06/2013
Operating Instructions
Agile