Motor Potentiometer; Fixed Frequency Changeover; Fixed Percentage Changeover - BONFIGLIOLI Agile Operating Instructions Manual

Frequency inverter 230 v / 400 0.09 kw ... 11 kw
Hide thumbs Also See for Agile:
Table of Contents

Advertisement

Parameter descriptions
3-wire control is activated with parameter
412
Local/Remote
5 - Control 3-wire
See chapter 7.3.1 "Control" for further operation modes of parameter
Parameter
87
Start 3-Wire Ctrl
7.6.6.4

Motor potentiometer

62 Frequency Motorpoti Up
63 Frequency Motorpoti Down
The reference frequency of the drive can be set via digital control signals. See chapter 7.5.3.3.1
"Control via reference frequency channel".
Parameter
Frequency Motorpoti Up
Frequency Motorpoti Down
72 Percent Motorpoti Up
73 Percent Motorpoti Down
The reference percentage can be set via digital control signals. See chapter 7.5.3.3.2 "Control via
reference percentage channel".
Paramete
62
Percent Motorpoti Up
Percent Motorpoti Down
7.6.6.5

Fixed frequency changeover

66 Fixed Frequency Change-Over 1
67 Fixed Frequency Change-Over 2
131 Fixed Frequency Change-Over 3
By combining the logic states of the fixed frequency changeover modes 1, 2 and 3, the fixed frequen-
cies 1 to 8 (parameters 480 to 488) can be selected. See chapter 7.5.1.3 "Fixed frequencies".
Parameter
Fixed Frequency Change-Over 1
Fixed Frequency Change-Over 2
Fixed Frequency Change-Over 3
7.6.6.6

Fixed percentage changeover

75 Fixed Percent Change-Over 1
76 Fixed Percent Change-Over 2
By combining the logic states of
76, the fixed percentages 1 to 4 (Parameters 520 to 523) can be selected. See chapter 7.5.2.3 "Fixed
percentages".
Parameter
Fixed Percent Change-Over 1
Fixed Percent Change-Over 2
Control inputs and outputs
Local/Remote
Control of direction of rotation (parameter
69) and signal
Anticlockwise
Factory setting
7 - Off
Factory setting
62
7 - Off
63
7 - Off
Factory setting
7 - Off
63
7 - Off
Factory setting
66
74 - IN4D
67
7 - Off
131
7 - Off
Fixed Percent Change-Over 1
Factory setting
75
7 - Off
76
7 - Off
201
412:
Function
Start Clockwise
87 via digital inputs.
Start 3-Wire Ctrl
Local/Remote
75and
Fixed Percent Change-Over 2
06/2013
Operating Instructions
68,
Start
412.
Agile