BONFIGLIOLI Agile Operating Instructions Manual page 109

Frequency inverter 230 v / 400 0.09 kw ... 11 kw
Hide thumbs Also See for Agile:
Table of Contents

Advertisement

Commissioning
SETUP Selection
Plaus.-Check Machine
21 -
Data, DS1
Plaus.-Check Machine
22 -
Data, DS2
Plaus.-Check Machine
23 -
Data, DS3
Plaus.-Check Machine
24 -
Data, DS4
Calculation and Para-
30 -
Ident., DS0
Calculation and Para-
31 -
Ident., DS1
Calculation and Para-
32 -
Ident., DS2
Calculation and Para-
33 -
Ident., DS3
Calculation and Para-
34 -
Ident., DS4
Para-Ident. Machine
40 -
Data only, DS0
Para-Ident. Machine
41 -
Data only, DS1
Para-Ident. Machine
42 -
Data only, DS2
Para-Ident. Machine
43 -
Data only, DS3
Para-Ident. Machine
44 -
Data only, DS4
797 Setup Status
The individual steps of the auto set-up routine can be monitored and checked via parameter
797. The setup routine via the communication interface continuously updates the status pa-
Status
rameter which can be read out via the interface.
Message
OK
PC Phase 1
PC Phase 2
STO
Parameter identifica-
tion
Setup already active
No Release
Error
Warning Phase Asym-
metry
Setup not carried out
If a warning message is output or an error occurs during Setup, refer to chapter 6.2.5 "Warnings dur-
ing commissioning".
Set-up via the Communication Interface
796
The rated motor parameters in data set 1 are checked for plausi-
bility.
The rated motor parameters in data set 2 are checked for plausi-
bility.
The rated motor parameters in data set 3 are checked for plausi-
bility.
The rated motor parameters in data set 4 are checked for plausi-
bility.
The auto set-up routine determines extended motor data via the
parameter identification feature, calculates depend-ent parameters
and stores the parameter values in all of the four data sets identi-
cally.
Further motor data are measured, dependent pa-rameters are
calculated and the parameter values are saved in data set 1
Further motor data are measured, dependent pa-rameters are
calculated and the parameter values are saved in data set 2
Further motor data are measured, dependent pa-rameters are
calculated and the parameter values are saved in data set 3
Further motor data are measured, dependent pa-rameters are
calculated and the parameter values are saved in data set 4
Extended motor data are measured and saved identically in all
data sets. Other parameter values already set are maintained.
Extended motor data are measured and saved data set 1. Other
parameter values already set are maintained.
Extended motor data are measured and saved data set 2. Other
parameter values already set are maintained.
Extended motor data are measured and saved data set 3.
Extended motor data are measured and saved data set 4. Other
parameter values already set are maintained.
Status messages
Auto set-up routine has been carried out.
The plausibility check of the motor data is active.
The calculation of dependent parameters is active.
The parameter identification demands enable on digital input STOA and
STOB.
The rated motor values are checked by the parameter identification feature.
The setup routine via the operator panel is being carried out.
No enable signal. The parameter identification demands enable on digital
input STOA and STOB.
Error during the auto set-up routine.
The parameter identification feature diagnosed an unbalance during the
measurements in the three motor phases.
The setup is not carried out until now.
Function
Meaning
109