Scaling
The analog input signal is mapped to the freely configurable characteristic. The maximum admissible
setting range of the drive can be set via the frequency limits or percentage limits. In the case of the
parameterization of a bipolar characteristic, the set minimum and maximum limits for both directions
of rotation are effective. The percentage values of the characteristic points are relative to the limits
selected.
Parameters
No.
Description
418 Minimum Frequency
419 Maximum Frequency
The control system uses the maximum value of the output frequency, which is calculated from the
419 and the compensated slip of the drive mechanism. The frequency limits
Maximum Frequency
define the speed range of the drive, and the percentage values supplement the scaling of the analog
input characteristic in accordance with the functions configured.
Parameters
No.
Description
518 Minimum Reference Percentage
519 Maximum Reference Percentage
450 Tolerance Band
The analog input characteristic with change of sign of the reference value can be adapted by the pa-
rameter
Tolerance Band
sage of the speed relative to the analog control signal. The parameter value (percent) is relative to
the maximum current or voltage signal.
Parameters
No.
Description
450 Tolerance Band
Pos. maximum value
0 V
(0 mA)
(X1/Y1)
Neg. maximum value
Without tolerance band
Hysteresis
The default
Minimum Frequency
ized tolerance band to the hysteresis.
Agile
Operating Instructions
Min.
0.00 Hz
0.00 Hz
Min.
0.00%
0.00%
450 of the application. The adjustable tolerance band extends the zero pas-
Min.
0.00%
(X2/Y2)
0 V
+10 V
(0 mA)
(+20 mA)
418 or
Minimum Reference Percentage
172
06/2013
Setting
Max.
Fact. sett.
999.99 Hz
3.50 Hz
999.99 Hz
50.00 Hz
Setting
Max.
Fact. sett.
300.00%
300.00%
100.00%
Setting
Max.
Fact. sett.
25.00%
(X2/Y2)
Pos. maximum value
zero point
tolerance band
(X1/Y1)
Neg. maximum value
With tolerance band
518 extends the parameter-
Control inputs and outputs
Parameter descriptions
0.00%
2.00%
+10 V
(+20 mA)