Fixed Frequencies
P480
Fixed Frequency 1
P481
Fixed Frequency 2
P482
Fixed Frequency 3
P483
Fixed Frequency 4
P485
Fixed Frequency 5
P486
Fixed Frequency 6
P487
Fixed Frequency 7
P488
Fixed Frequency 8
P66
7
Off
P67
71
IN1D
P131
72
IN2D
73
IN3D (P558: 0 - Input)
74
IN4D
75
IN5D
76
MFI1D(P452: 3 - NPN or 4 - PNP)
77
MFI2D (P562: 3 - NPN or 4 - PNP)
...
other signal sources
Via the signal states at the digital inputs, the fixed frequencies can be selected.
P475 or P492: 3 - Fixed Frequency.
The Speed Control is always limited by the Minimum Frequency (P418) and Maximum
Frequency (P419).
Blocking Frequencies
Reference frequencies are hidden. Mechanical resonance of the plant can be avoided.
Two blocking frequencies can be set.
P447
1st Blocking Frequency (0.00 Hz)
P448
2nd Blocking Frequency (0.00 Hz)
P449
Frequency Hysteresis (0.00 Hz)
Select the frequency range to be hidden.
In this range, there is no stationary op-
erating point.
PWM input
A PWM signal at input IN2D (X11.5) can be used as reference value.
P496
10
PWM, 0 ... 100%
11
PWM, -100 ... 100%
P652 and P653; for scaling
P476 or P494:
The Speed Control is always limited by the Minimum Frequency (P418) and Maximum
Frequency (P419).
Agile
Operating Instructions
(0.00 Hz)
(10.00 Hz)
(25.00 Hz)
(50.00 Hz)
(5.00 Hz)
(10.00 Hz)
(25.00 Hz)
(50.00 Hz)
of P419 (maximum frequency) or of P519 (maximum
reference percentage)
10
Repetition percentage
86
06/2013
P66
P67
0
0
1
0
1
1
0
1
0
1
1
1
1
0
0
0
Reference
value
output
P449
P447
f
- hysteresis
Blocking
P447 - P449
After first commissioning
Commissioning
(Factory setting)
P131
Selection
0
P480
0
P481
0
P482
0
P483
1
P485
1
P486
1
P487
1
P488
(Factory setting)
P449
Reference value
internal
f
+ hysteresis
Blocking
P447 + P449