11.3

Control electronics

Voltage output DC 24 V
Terminals
Maximum output current
Voltage output DC 10 V
Terminal
Maximum output current
Minimum output current
Voltage input DC 24 V
Terminal
Input for external power supply.
Input voltage range
Rated input current
Input peak current
External fuse
Safety
Digital inputs
Terminals
Signal level
Maximum input voltage
Input resistance
Response time
Other properties
Digital inputs for enable and safety function STO
Terminals
Signal level
Maximum input voltage
Input resistance
Response time
Digital output
Terminal
Output voltage
Maximum output current
Other properties
1
Depending on value at 24 VDC voltage input.
2
Connect ground (GND) of external power supply to terminal X13.2 (GND).
3
The value is reduced if additional control outputs are used.
Agile
Operating Instructions
X11.1 (DC +24 V), X11.2 (DC 0 V)
DC 100 mA
X13.4
DC 8.2 mA
1
DC 2.3 mA
X13.1 (DC 24 V), X13.2 (DC 0 V)
2
DC 24 V ±10%
Max. DC 1.0 A (typically DC 0.45 A)
Typically < DC 15 A (max. 100 µs)
Standard fuse elements for rated current, characteristic: slow
Safety extra low voltage SELV according to EN 61800-5-1
X11.4, X11.5, X12.1, X12.2
PNP
High: DC 15...24...30 V
NPN High: DC 0...5
DC 30 V (DC 6 mA at DC 24 V)
3.9 kΩ
2 ms
PLC compatible
X11.3, X13.3
Low:
DC 0 ... 3 V
High: DC 15 ... 30 V
DC 30 V (DC 10 mA at DC 24 V)
1.8 kΩ
Enable is activated 10 ms after triggering.
X13.5
DC 22 V (DC 15 ... 28 V)
3
DC 100 mA
Overload and short-circuit proof, overvoltage-protected
286
06/2013
Technical data
Low: DC 0...5
V
Low: DC 15...24...30
Control electronics
V
V

Hide quick links:

Advertisement

Table of Contents
loading