This Quickstartguide contains the description for the mechanical installation with the Standard mounting kit. For other mounting variants (in example Cold Plate) please comply with the Operating instructions. The German documentation is the original one. Other language versions are translated. The different instructions can be downloaded from the website www.Bonfiglioli.com. Quickstartguide AGL...
Page 3
Do not remove covers during operation. Please note, that Bonfiglioli Vectron does not take any responsibility for the compatibility of external products (e.g. motors, cables, filters, etc.). Using the device in combination with external products is carried out at your own risk.
elsto.eu Voorhout • Groningen • Weert • Hoogerheide +31(0)88 7865800 Proper use The product is an electrical drive component. It is applicable for installation in machines or electrical plants the control of three-phase asynchronous motors and synchronous motors. industrial environments Transport and Storage Ambient temperature:-25 ...
“Functional Safety”. [2] Labeling for UL508c (if applicable). Recommended motor shaft at specified power supply Specifier Frame size AGL 202: AC AGL 202: AC AGL 402: AC 3x400 V 3x230 V 1x230 V -01 1 0.18 kW 0.09 kW -02 1 0.25 kW...
elsto.eu Voorhout • Groningen • Weert • Hoogerheide +31(0)88 7865800 Process of the commissioning Assembly Frame size 1 Frame size 2 Frame size 3 Mains connection Motor connection Connection of control lines Operation via control- Operation via Comissioning signals operator panel Setup via operator panel Start drive Refer to the corresponding section.
Page 7
elsto.eu Voorhout • Groningen • Weert • Hoogerheide +31(0)88 7865800 Assembly Warning! Make sure, that no foreign particles (e.g. dust, metal shavings, wires, screws, tools) can get inside the frequency inverter. Install the frequency inverter on a non-flammable mounting plate. Installation in bottom-up or horizontal position is not permissible.
elsto.eu Voorhout • Groningen • Weert • Hoogerheide +31(0)88 7865800 Mains connection Danger! Switch off power supply Dangerous voltage: The power terminals may carry dangerous voltages for some time even if the power supply is switched off. Wait for some minutes before starting to work at the frequency inverter.
elsto.eu Voorhout • Groningen • Weert • Hoogerheide +31(0)88 7865800 Connection on IT mains configuration For connection on IT mains configuration remove the IT- jumper Note: The removal oft the IT jumper reduces the noise immunity. The noise immunity can be improved by external filters. Motor connection Danger! Switch off power supply.
elsto.eu Voorhout • Groningen • Weert • Hoogerheide +31(0)88 7865800 Type -02…-11 3~400 V 0.25…1.5 U,V,W 2 x 1.5 2 x 2.5 2 x 4 1 x 10 1 x 10 1 x 10 Type -01…-07 -11…-13 3~230 V 0.18…0.75 1.5…2.2 U,V,W 2 x 1.5...
Page 11
elsto.eu Voorhout • Groningen • Weert • Hoogerheide +31(0)88 7865800 Wiring of control cables Danger! Switch off power supply before connecting or disconnecting terminals. Use shielded control cables. Connect the conductor shielding of the control cables to ground potential by means of the shielding clamp.
Page 12
Select, if further motor parameters are to be measured automati- tvne cally. Tvning Measurement of motor data. Select, if the data of a BONFIGLIOLI motor entered. CALC The pre-settings of other motor data are loaded. Acceleration clockwise, factory setting 5Hz/ s Deceleration clockwise, factory setting 5Hz/ s...
elsto.eu Voorhout • Groningen • Weert • Hoogerheide +31(0)88 7865800 Keys Increase speed in mode "Motor- Start the drive poti". Scroll up to parameter STOP Stop the drive. numbers. Increase parameter values. Cancel. Return to the previous menu. Decrease speed in mode "Motor- poti".
Page 14
elsto.eu Voorhout • Groningen • Weert • Hoogerheide +31(0)88 7865800 Function of control terminals 1 voltage input DC 24 V − 6 digital inputs, 2 of them for − Enable 2 voltage outputs, − 1 digital input/ output − DC 10 V and DC 24 V 2 multifunction inputs: −...
Page 15
elsto.eu Voorhout • Groningen • Weert • Hoogerheide +31(0)88 7865800 Error messages and warnings during setup Error messages Fault clearance Check rated motor values in parameters 370…376. Correct the values if SF001 SF022 necessary. Repeat Setup. Check motor cable connections and frequency inverter connections.
Page 16
elsto.eu Voorhout • Groningen • Weert • Hoogerheide +31(0)88 7865800 Warnings Frequency inverter overloaded. Check load behavior. Check motor parameters and A0001 A0004 application parameters. A0008 A0010 Overtemperature. Check cooling, fan and ambient temperature. Max. motor temperature reached, check motoer and sensor. A0080 Mains phase failure, check mains fuses and supply cable.
Page 17
elsto.eu Voorhout • Groningen • Weert • Hoogerheide +31(0)88 7865800 Applications via control terminals Select out- X12.1 Fixed frequency change-over via two digital inputs. put fre- X… Set P492=3. Set frequency values in P480 ... 483. quency Select digital inputs P66 and P67.Select a frequency value via P66 und P67.
Communication interface X21 with RJ45 connection For serial RS485 communication via VA Bus or Modbus protocol. BONFIGLIOLI Vectron provides an interface adaptor for the USB connection of a PC. This enables parametrization and monitoring via the PC software VPlus. Parameter copy Parameter values can be stored on a memory card („Ressource Pack“) and transferred from...
elsto.eu Voorhout • Groningen • Weert • Hoogerheide +31(0)88 7865800 Device data General are valid for AGL202 and AGL402 devices are the following characteristics: Output motor side Output voltage U V Maximum value of input voltage, three-phase Protection - - Short circuit proof and earth fault proof Rotary field frequency f Hz 0 ...
Page 20
elsto.eu Voorhout • Groningen • Weert • Hoogerheide +31(0)88 7865800 AGL202 (3~:0.18 … 0.55 kW, 1~:0.09 … 0.25 kW, 230 V) Type 230 V Agile Size Output motor side Selected Mains supply Recommended kW 0.09 0.18 0.12 0.25 0.18 0.37 0.25 0.55 motor shaft power Output current...
elsto.eu Voorhout • Groningen • Weert • Hoogerheide +31(0)88 7865800 Technical data of control terminals Voltage X11.1 DC 24 V, Imax =100 mA. Appropriate GND: X11.2. outputs X13.4 DC 10 V, Imax =2.3 mA (dependent on level of DC 24 V voltage input), Imax = 8.2 mA Input for external voltage supply.