Operation Diagrams - BONFIGLIOLI Agile Operating Instructions Manual

Frequency inverter 230 v / 400 0.09 kw ... 11 kw
Hide thumbs Also See for Agile:
Table of Contents

Advertisement

Relay output (floating changeover contact)
Terminal
Contact load capacity
Response time
11.4

Operation diagrams

Installation height
The nominal values of the frequency inverter apply to installation altitudes up to 1000 meters above
1
sea level
. If the installation altitude exceeds 1000 meters, the output power and cooling agent tem-
perature (ambient temperature) must be reduced.
Reduction of output current
Power reduction (derating).
Above 1000 m: Reduction by 5%/1000 m.
Maximum altitude 3000 m.
I [%]
100
95
90
0
1000
2000
Reduction of output current I depending on installa-
tion altitude H.
1
NN: sea level
Agile
Operating Instructions
X10
make
AC 240 V/5 A, DC 24 V/5 A (ohmic)
contact:
break
AC 240 V/3 A, DC 24 V/1 A (ohmic)
contact:
40 ms
Reduction of cooling agent temperature
Above 1000 m: Reduction by 3.3°C/1000 m.
Maximum cooling agent temperature 55 °C.
T [°C]
55
52
48
H [m]
3000
Reduction of cooling agent temperature T
depending on installation altitude H.
288
06/2013
0
1000
2000
Operation diagrams
Technical data
3000
H [m]

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents