Control signals
Selection for parameter
170 - Warning Overtemperature
175 - Digital Signal OUT1D
176 - Digital Signal OUT2D Relay Signal selected via
177 - Digital Signal OUT3D
Reference Percentage
178 -
reached
179 - Mains Failure
Warning Motor Protection
180 -
Switch
181 - Digital Signal MFO1D
215 - Warning Mask, Application
216 - Application Warning
Technology Controller
219 -
within Backlash
264 - Warning service DC-link
265 - Warning service fan
270 to 277
284 - STOA inverted
285 - STOB inverted
292 - STOA
293 - STOB
323 - Power is on
Energy saving function is
471 -
active
Agile
Operating Instructions
The value
− (Maximum heat sink temperature T
407) or
Heat Sink Temp.
− (Maximum inside temperature T
408)
side Temp.
was reached.
Signal selected via
Op. Mode OUT1D (X13.5)
Op. Mode OUT2D (X10/Relay)
Signal selected via
Op. Mode OUT3D (X11.6)
Signal when the
Actual Percentage Value
Reference Percentage Value
Failure of the mains voltage and power regulation active accord-
ing to
Operation Mode
Parameterized
Operation Mode
triggered.
Signal selected via
Digital: Source MFO1D
The defined warning mask of parameter
626 signals a critical operating point.
Mask
All Application Warnings are deactivated. Display is effected via
parameter
Application Warnings
The control deviation lies within the range defined by
618.
lash
Signal if the time remaining until service has expired. Parameter
Operation Mode Service Interval DC-link
"2 - Alarm Message". Parameter
plays a message.
Signal if the time remaining until service has expired. Parameter
Operation Mode Service Interval Fan
Alarm Message". Parameter
message.
Operation modes 70 to 77 of the digital inputs inverted (LOW
active).
Inverted signal status on digital input STOA for enable.
Inverted signal status on digital input STOB for enable.
Signal status on digital input STOA for enable.
Signal status on digital input STOB for enable.
Signal if mains voltage is switched on and pre-charging is fin-
ished.
Parameter
Operation mode energy saving function
to "1 - manual" or "2 - automatic". The digital input or logic sig-
nal selected for parameter
switched on the energy saving function.
198
06/2013
Parameter descriptions
Function
) minus (
K
) minus (
Warning Limit In-
i
531.
533.
230 has reached the
229.
670 for the voltage controller.
571 of the motor circuit breaker
554.
Create Appl. Warning
273.
1534 must be set to
Maintenance Note
1535 must be set to "2 -
1533 displays a
Maintenance Note
Energy saving function on
Control inputs and outputs
Warning Limit
532.
Back-
1533 dis-
1550 is set
1552 has

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents