Parameter descriptions
WARNING
The control functions listed in the following table may affect the synchronous operation
of the drives. It should be checked if these additional control functions are switched on
and if they are required.
Parameters
573 Operation mode
610 Operation mode
660 Operation mode
670 Operation mode
164 n/T Control change over
475 Reference Frequency Source 1
492 Reference Frequency Source 2
Via parameter
Controller Status
The function of the electronic gear is realized by configuring digital inputs of the slave frequency in-
verter as a reference frequency input. If the master drive is a frequency inverter, the repetition fre-
quency output of the master frequency inverter is used.
7.5.4.6.1 Frequency inverter as master drive
If the master drive of the electronic gear is a frequency inverter, the following parameters (for exam-
ple) can be set for the transmission of the repetition frequency.
Select operation mode "20 – Repetition Frequency MFO1F" for parameter
550. As a result, the multifunction output is used as a repetition frequency output.
(X13.6)
Via parameter
RF/PT: Output Value MFO1F
output 1.
Set the value entered for parameter
at the repetition frequency output. This is the number of pulses per motor revolution for the repe-
tition frequency. The pulse duration depends on the motor speed. By default, this parameter is set
to 1024. When making the settings, take the frequency limit of the frequency output of 150 kHz
into account. The maximum value S
is:
150
000
Hz
S
=
max
Frequency
value
7.5.4.6.2 Frequency inverter as slave drive
For the function of the electronic gear via the repetition frequency, the following parameters (for ex-
ample) can be set at the frequency inverter of the Slave drive.
For parameter
Operation Mode IN2D
Evaluation" (RF: Repetition Frequency). Digital input IN2D is the repetition frequency input. See
chapter 7.6.7.2 "Repetition frequency input".
Since the rated speed decreases when the number of pole pairs is higher (n~1/p), different
speeds may result if the master drive and slave drive have the same reference frequencies. Adjust
the values for parameters
556 of the repetition frequency output of the master according to the num-
RF: Division marks
ber of pole pairs of the motors in order to obtain the same speeds for the master drive and the
slave drive. Different speeds can be realized by setting the gear factor.
Different values for parameters
drive and
RF: Division Marks
speeds of the master drive and the slave drive if the number of pole pairs of the motors is the same.
Reference Values
Function
Intelligent current limits
Current limit value controller
Slip compensation
Voltage controller
Switch over Torque control
Added reference frequency value
275, you can display if a controller is active.
555, select an operation mode for multifunction
RF: Division Marks
which can be set for parameter
max
496 select: "20 - RF Single Evaluation" or "21 - RF Double
497 of the repetition frequency input of the slave drive and
Divider
497 of the repetition frequency input of the slave
Rep. Freq: Divider
556 of the repetition frequency output of the master result in different
167
Operation Mode MFO1
556 according to the frequency required
RF: Division Marks
06/2013
Operating Instructions
556
Agile